Satisfaction guaranteed. Call us anytime: 1-877-880-TILE (8453).
Cart: 0 items, $0.00

Your shopping cart is empty.

Checkout

SunTouch Programmable SunStat Control – Specification

January 25, 2010

SunTouch Programmable SunStat Control 500670 SB – Specification

By SunTouch® A division of Watts Water Technologies, Inc.

Heated floor mat, heat mat, radiant floor heat mat, radiant floor heating supply, radiant floor heating mat, radiant floor mat, flooring heating System, tile heating,

Installation Guide

Review

In addition to the features for the Non-programmable SunStat, the Programmable SunStat has a built-in seven day timer function to turn the system on when you desire and to turn it off when you leave home.

Many people believe the extra cost can quickly be recovered in energy savings by using this electric radiant floor heat control.

Dual Voltage for both 120 VAC and 240 VAC

Features include a floor sensor that directly senses floor temperature, 15-amp capacity controlling up to 150 sq. ft. of 120-VAC mats or 300 sq. ft. of 240-VAC mats; built-in ground fault protection with no need for a separate GFCI (in most code areas) large, back-lit digital display
temperature range of 40° to 104°F.

Temperature display in °F or °C; on/off switch; 12 or 24-hr. clock.

Specifications – 500670

Programmable Control Model 500670
Power Supply 120/240 VAC 50/60 Hz
Maximum Load 15 amps, resistive
Maximum Power 1800 watts at 120 VAC 

3600 watts at 240 VAC

GFCI Class (5 millamp trip) 

Display Range 32°F to 140°F (0°C to 60°C)
Setting Range 40°F to 99°F (4°C to 37°C)
Accuracy + 0.9°F (0.5°C)
Storage Temp 0°F to 120°F (0°C to 49°C)
Memory Programming Retained Indefinitely 

Current time and day will need re-set if power is lost more than 30 minutes

ETL Listing Control No. 3037530

Material

• One (1) power base

• Two (2) 6-32 screws 1-1/4 in.

• Four (4) solder less connectors for copper wires

NOTE: Special CO/ALR solder less connectors must be used when connecting with aluminum conductors.

• One (1) temperature sensor with a 15-ft. (4.5-meter) extension

• One (1) flat-tip screwdriver.

Installation Guidelines

Turn off power to the heating system at the main power panel to avoid electrical shock.

Keep the SunStat`s air vents clean and free from obstructions. Installation should be carried out by electricians or experienced technicians.

• High voltage SunStat must be installed onto an electrical box.
• For a new installation, choose a location about 5 ft. (approximately 1.5 meters) above the floor, with good air circulation.

• The SunStat must be installed facing the heating system.

• The SunrStat must be installed on an inside wall.

• Avoid locations where there are air drafts (top of staircase, air outlet), dead air spots (behind a door), direct sunlight or concealed chimneys or stove pipes.

Heated floor mat, heat mat, radiant floor heat mat, radiant floor heating supply, radiant floor heating mat, radiant floor mat, flooring heating System, tile heating,

Loudmouth, Heated floor mat, heat mat, radiant floor heat mat, radiant floor heating supply, radiant floor heating mat, radiant floor mat, flooring heating System, tile heating, floor heat cable, radiant flooring, radiant floor heat system, floor warming system, heated floor system, under floor heat

Installation Steps

The GFCI monitors electricity flow for any loss of current; if there is, the SunStat immediately cuts power to the heating system.

We recommend you test the GFCI right after installing the control module, and once a month thereafter to ensure it is operating properly.

To test

1. Press the TEST button:

• Successful: Test warning light is ON and power to heating system is cut-off.

• Unsuccessful: Test warning light is OFF.

Cut power to heating system from the main power panel and call technical service.

2. When successful, reset SunrStat (On/Standby) to power the heating system.

NOTE: If the warning light comes on during normal operation, cut power to heating system from the main power panel and have an electrician verify the installation.

Dimensions

Face Size
Overall Size
Width: 2 7/8″
Width: 2 7/8″
Height: 4 9/16″
Height: 4 9/16″
Depth: 13/16″
Depth: 1 3/4″
Technical Specifications 500670
Models:
500670-120CS (120 VAC)
Setting range:
59°F to 95°F (15°C to 35°C): minimum: 45°F (7°C)
Potentiometers:

Minimum: 41°F to 77°F (5°C to 25°C)

Maximum: 59°F to 95°F (15°C to 35°C)

Accuracy:
0.9°F (0.5°C)
Storage:
-4°F to 120°F (-20°C to 50°C)
Features and Specifications
500670
500675
500680
Dual Voltage 120/240 Volt 50/60
X
X
X
Floor Sensing Control
X
X
Air-Sensing Control Capability
X
X
Regulator (no sensor) Control
X
X
SmartSrart Technology
X
X
“Master” Control Capability
X
X
Manual Temperature Setback
X
X
X
Manual On/Off Switch
X
X
X
Class 2 Insulated Sensor ( 15 Ft. long)
X
X
Large Backlight Digital Display
X
X
Keyboard Lockout
X
X
Remote Control
X
X
Fahrenheit and Celsius Format
X
X
12-hour 24-hour clock display
X
X
15-amp (resistive) Relay output
X
X
X
Class A (5 milliamp trip) GFCI
X
X
X
5/1/1 Day Programming
X
Four preset Schedules
X
One User Set Schedule
X
Usage Monitoring
X
Display Range ———-32-140F (0-60C)
X
X
Setting Range ———-40 TO 99 F (4 TO 37C)
X
X
Programming Retained Indefinitely
X
X
Listed by ETL for USA and Canada
X
X
X

Specifications – 500680 Relay Control

FEATURES

• Convenience: controls up to 10 slave units from a single master thermostat. Each Slave Unit can handle up to 15 amps.

• Controls slave units operating on different line voltages.

• Versatility: works with programmable and non-programmable models.

• Floor sensor enables precise control of floor temperature.

• Advanced temperature control ensures total comfort by minimizing temperature variations.

• Battery free.

SunStat Relay Slave Unit 500680
Power Supply
120/240 VAC 50/60 Hz
Maximum Load
15 amps, resistive
Maximum Power

1800 watts at 120 VAC

3600 watts at240 VAC

GFCI Class (5 millamp trip)
Storage Temp
0°F to 120°F (0°C to 49°C)
ETL Listing
Control No. 3037530

If a mat or cable system requires more than 15 amps, we recommend installing SunStat Relays.

SunTouch’s new SunStat™ Relays System is specially designed for large floor

heating applications exceeding 15 amps.

Here’s how it works:

Relays connect directly to SunStat thermostats for simple, elegant control of larger system.

SunStat Relays don’t require a special “master thermostat”, as before with the older version, this new Relays are dual voltage 120 VAC or 240 VAC, have a 15-amp capacity, and on/off switch and GFCI and test light.

It’s possible to control over 1500 sq. ft. of electric floor warming using 120 VAC and cover 3,000 VAC sq. ft floor warming mats or cables.

SunStat Relay

• Programmable and Non-programmable models available

• Controls up to 10 slave units (120vac & 240vac)

• Low voltage wiring means SunStat Relay can be installed anywhere

• Silent operation

The new SunStat™ Relays System is specially designed for large floor

heating applications exceeding 15 amps. Here’s how it works:

First, find the amp draw for each SunStat, UnderFloor or Warm Wire product on our web site, or on our more information section, then determine how many can connect to each relay. Up to ten 15-amp Relays can connect to one SunStat.

Ten Relays. Plus the internal relay in the SunStat, provide a total capacity of 165 amps! Each Relay should be connected to individual 20 amp breakers, as shown in this page picture

WARRANTY

WATTS RADIANT, INC. ONE (1) YEAR LIMITED WARRANTY

This product is warranted against defects in material and workmanship
occurring during normal use for a period of one year from the date of the
original purchase from authorized dealers.

During this period, Watts
Radiant, Inc. will repair or replace with a new or equivalent quality
product without charge at Watts Radiant, Inc.’s option, any product proven by Watts Radiant, Inc. to be defective in normal use.

Warranty does not cover transportation costs, nor does it cover a product subjected to misuse or accidental damage.

This warranty does not
cover the cost of installation, removal or reinstallation of the product or
associated materials and labor.

This limited warranty is in lieu of all other warranties, obligations or liabilities expressed or implied by the company. In no event shall Watts Radiant, Inc. be liable for consequential or incidental damages resulting from installation of this product.

Some states or provinces do not allow limitations on how long an implied warranty lasts, or the exclusion or limitation of incidental or consequential damages, so the above exclusions or limitations may not apply to you.

This warranty gives you specific legal rights and you may also have other rights which vary from state to state.

The defective product and the original sale receipt must be returned to the us pre-paid and insured to:

International Flooring Center, Inc. / flooringsupplyshop.com.
5047 W Jefferson Blvd
Los Angeles, CA 90016

www.suntouch.com

Click here for SunTouch VIDEO Library

SunTouch vs. Product A SunTouch vs. Product B

SunTouch Floor Heating Mat Links

SunTouch Mats Spec and installation SunTouch Mat SpecificationUnderfloor Spec and Installation

SunTouch Floor Heating Spool Links

SunTouch WarmWire Installation Guidelines SunTouch WarmWire StrapWarmWire Installation GuidelinesWarmWire Order Instruction and Information

Heating Controls Links

Programmable SunStat SpecOwner’s Manual Programmable 500670-SBOwner Manual Non Programmable 500675

SunStat Non Programmable Spec SunStat Relays ControlLoudMouth Operating Instruction

Misc SunTouch Links

SunTouch 25 year Limited Warranty EMF Electromagnetic fields Frequently Asked Questions Repair Heating Wire Suntouch Low Price Guarantee

The post SunTouch Programmable SunStat Control – Specification first appeared on Flooring Supply Shop Blog.

Leave a Reply

Your email address will not be published. Required fields are marked *

Chat with us Chat