Item#: 12787
SKU: PLG-DCM-120  |  Barcode: 815846015114

Warmup PLG-DCM-12 Plastic Fixing Strips for NADCM Cable - Box of 10

Regular price $1295
Shipping calculated at checkout.


Pickup available at 5047 West Jefferson Boulevard

Usually ready in 1 hour

Delivery and Shipping

  • Orders are shipped via USPS, UPS, or FedEx.
  • Shipping time up to 5 business days. Weekends not included.
  • Express shipping options available.
  • Same-day shipping cut-off time 4:00 PM PST for most items.
  • For oversized shipments that require freight delivery, our team will contact you.

If your address is unable to receive deliveries from USPS, UPS, or FedEx, please contact us.

Description

Warmup PLG-DCM-12 Plastic Fixing Strips for NADCM Cable System - Box of 10

The Warmup PLG-DCM-12 Plastic Fixing Strips provide a convenient and reliable way to secure Warmup NADCM and DCM-PRO heating cable directly to the subfloor. Designed for installations using loose heating cable without a DCM-PRO membrane, these strips help maintain consistent cable positioning and spacing during electric floor heating installation.

Each 12-inch fixing strip features positioning guides spaced in 1-inch increments, allowing installers to arrange the heating cable according to the required floor heating layout. The strips can be secured directly to the subfloor and easily cut to accommodate room dimensions, corners and irregular floor layouts.

FEATURES & BENEFITS

  • Designed for Warmup Heating Cable: Used to secure NADCM and DCM-PRO heating cable during loose cable installations.
  • 12-Inch Strip Length: Convenient length for positioning and securing heating cable across the floor.
  • 1-Inch Spacing Increments: Integrated positioning guides allow flexible heating cable placement.
  • Durable Plastic Construction: Approximately 3/16-inch thick for holding cable in position during installation.
  • Easy to Cut: Can be trimmed with ordinary tin snips to accommodate different floor layouts.
  • Secure Cable Placement: Helps prevent heating cable from shifting or lifting during installation.
  • Flexible Installation: Strips can be secured to the subfloor using suitable adhesive, nails, screws or strong double-sided tape.
  • Convenient Package: This listing includes 10 individual 12-inch strips, providing 10 linear feet in total.

HOW TO USE WARMUP FIXING STRIPS

Warmup fixing strips are used to establish and maintain the desired heating cable layout when installing the loose cable system without an uncoupling membrane.

  • Prepare the subfloor so it is clean, dry and suitable for installation.
  • Position the fixing strips according to the planned heating cable layout.
  • Keep the strips at least 3 inches away from the wall in the direction perpendicular to the planned cable runs.
  • Install additional fixing strips approximately every 3 to 4 feet across the floor to stabilize the cable layout.
  • Secure the strips using suitable adhesive, nails, screws or strong double-sided tape.
  • Lay the Warmup heating cable into the positioning guides at the required spacing.
  • Maintain the specified cable spacing and ensure the heating cable remains securely positioned during installation.

HEATING CABLE SPACING

The integrated 1-inch positioning increments allow installers to create different cable layouts depending on the heating requirements of the project.

Warmup identifies 3-inch cable spacing as the UL-approved minimum when using fixing strips. Always follow the cable manufacturer's installation manual and the approved heating layout for the selected cable.

PRODUCT SPECIFICATIONS

  • Product Type: Plastic Heating Cable Fixing Strips
  • Compatible Cable: Warmup NADCM and DCM-PRO Heating Cable
  • Strip Length: 12 inches
  • Strip Thickness: Approximately 3/16 inch
  • Spacing Increments: 1 inch
  • Quantity: 10 strips per listing
  • Total Linear Length: 10 feet
  • Cutting: Ordinary tin snips
  • Installation: Adhesive, nails, screws or strong double-sided tape

ESTIMATING YOUR MATERIAL REQUIREMENTS

As an approximate planning guideline, your listed usage is 20 linear feet of fixing strips per 35-45 square feet of heated floor area. Actual requirements depend on the room dimensions, cable layout and fixing strip placement.

WHY USE WARMUP PLASTIC FIXING STRIPS?

Proper heating cable positioning is important for achieving an organized and consistent electric floor heating installation. Warmup fixing strips provide a practical alternative to using an uncoupling membrane, allowing installers to secure loose heating cable directly to a properly prepared subfloor.

With adjustable 1-inch positioning increments and convenient 12-inch lengths, these fixing strips are a useful installation accessory for professional floor heating installers and contractors.

IMPORTANT INSTALLATION INFORMATION

These fixing strips are designed for use with compatible Warmup heating cable systems. They are cable positioning accessories and do not provide heating or electrical control. Follow the complete Warmup installation manual for cable spacing, subfloor preparation, electrical testing and installation requirements.


HELPFUL RESOURCES


SHOP RELATED COLLECTIONS

Payment & Security

Payment methods

  • Amazon
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Venmo
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.