{"title":"Warmup Snow Melt Cables","description":"","products":[{"product_id":"warmup-snow-and-ice-melting-cable-20-34-sq-ft-wsm","title":"Warmup Snow and Ice Melting Cable WSM 20-34 sq ft 240V\/480V","description":"\u003ch4\u003eWarmup Snow and Ice Melting Cable WSM - 20 to 34 sq ft Coverage\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eAvailable Voltage:\u003c\/strong\u003e 240V \u0026amp; 480V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSuitable for Installation Under:\u003c\/strong\u003e Asphalt, Concrete, and Pavers\u003c\/p\u003e\n\u003cp\u003eThe Warmup WSM Snow Melting Cable is designed to prevent snow and ice buildup on driveways, walkways, ramps, stairs, parking areas, sidewalks, and other outdoor surfaces. These energy-efficient outdoor heating cables are suitable for installation under concrete, asphalt, or paver systems and provide reliable snow melting performance for residential and commercial applications.\u003c\/p\u003e\n\u003cp\u003eWarmup snow melting cables feature a durable twin-conductor design with a single-point power connection and include a 10-Year manufacturer warranty.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Coverage \u0026amp; Electrical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e240V Model\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Length:\u003c\/strong\u003e 84 ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistance:\u003c\/strong\u003e 57.1 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmperage:\u003c\/strong\u003e 4.2 Amps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput:\u003c\/strong\u003e 1000 Watts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoverage at 3\" Spacing:\u003c\/strong\u003e 20 sq ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoverage at 4\" Spacing:\u003c\/strong\u003e 27 sq ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoverage at 5\" Spacing:\u003c\/strong\u003e 34 sq ft\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e480V Model\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Length:\u003c\/strong\u003e 84 ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistance:\u003c\/strong\u003e 230.77 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmperage:\u003c\/strong\u003e 2.08 Amps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput:\u003c\/strong\u003e 1000 Watts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoverage at 3\" Spacing:\u003c\/strong\u003e 20 sq ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoverage at 4\" Spacing:\u003c\/strong\u003e 27 sq ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoverage at 5\" Spacing:\u003c\/strong\u003e 34 sq ft\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eKey Advantages\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e16 ft cold lead with single-point connection\u003c\/li\u003e\n\u003cli\u003eSuitable for installation in sand, gravel, concrete, asphalt, or on wire mesh\u003c\/li\u003e\n\u003cli\u003eEnergy-efficient twin-conductor heating cable design\u003c\/li\u003e\n\u003cli\u003eIdeal for heated driveways, ramps, sidewalks, stairs, and walkways\u003c\/li\u003e\n\u003cli\u003eSupports full coverage or tire-track snow melting layouts\u003c\/li\u003e\n\u003cli\u003eDesigned for residential and commercial snow melting applications\u003c\/li\u003e\n\u003cli\u003eCompatible with Warmup snow sensors and automatic controls\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe Warmup WSM heating cable is commonly installed in concrete pours, asphalt driveways, paver walkways, loading areas, and commercial outdoor snow melting systems. Embedded up to 4 inches deep, the cable can be configured for full surface snow melting coverage or vehicle tire-track systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Voltage:\u003c\/strong\u003e 240V \u0026amp; 480V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat Output:\u003c\/strong\u003e ± 50 Watts per sq ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Construction:\u003c\/strong\u003e Twin-conductor fluoropolymer insulated heating cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Diameter:\u003c\/strong\u003e 1\/4\" (6mm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Exposure Temperature:\u003c\/strong\u003e 464°F (240°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Lead Length:\u003c\/strong\u003e 16.4 ft (5m)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 10-Year Manufacturer Warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications \u0026amp; Installation Information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible Surface Materials\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePavers and masonry surfaces\u003c\/li\u003e\n\u003cli\u003eConcrete slabs and walkways\u003c\/li\u003e\n\u003cli\u003eAsphalt driveways and parking surfaces\u003c\/li\u003e\n\u003cli\u003eOutdoor stairs and ramps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible Base Materials\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCrushed gravel base\u003c\/li\u003e\n\u003cli\u003eSand bed\u003c\/li\u003e\n\u003cli\u003eInsulation boards and sheets\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eRecommended Coverage Depth\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Coverage:\u003c\/strong\u003e 2 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Coverage:\u003c\/strong\u003e 4 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation Under Pavers\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor paver applications, the heating cable should be covered with approximately 2 inches of sand before installing the pavers. Pavers should not exceed 4 inches in thickness.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation Under Asphalt\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe WSM cable can withstand direct asphalt contact for a limited time until the asphalt cools. For asphalt pours exceeding 220°F, apply a 2-inch sand layer above the cable before asphalt placement. Rollers exceeding 2 tons should not be used directly over the heating cable. Hand rolling is strongly recommended.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation Under Concrete\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor concrete installations, ensure the cable is embedded no deeper than 4 inches below the finished surface. Re-mesh or wire mesh is recommended to properly suspend the cable within the slab during the concrete pour.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty \u0026amp; Maintenance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen installed according to Warmup installation guidelines and properly tested throughout installation, the WSM snow melting cable system requires virtually no maintenance during its operational life. The cable is backed by Warmup’s 10-Year manufacturer warranty and protected by the Warmup SAFETYnet installation guarantee.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eHelpful Resources\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/do-it-yourself\/warmup-snow-melting-questions-answers\"\u003eWarmup Snow Melting Installation Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0927\/8839\/2257\/files\/warmup_snow_melting_Installation_instructions.pdf?v=1748782050\"\u003eWarmup Snow Melting Specifications \u0026amp; Installation Instructions PDF\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eRelated Collections\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/warmup-snow-melt\"\u003eShop All Warmup Snow Melting Systems\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/warmup-heating-mats\"\u003eShop Warmup Snow Melting Mats\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/warmup-heating-cables\"\u003eShop Warmup Snow Melting Cables\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/warmup-thermostats-accessories\"\u003eShop Warmup Thermostats \u0026amp; Accessories\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Warmup","offers":[{"title":"240 Volt","offer_id":50492110766401,"sku":"WSM-240-1000-240-volt","price":256.0,"currency_code":"USD","in_stock":true},{"title":"480 Volt","offer_id":50492110799169,"sku":"WSM-240-1000-480-volt","price":269.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0927\/8839\/2257\/files\/warmup_snow_melting_cable_wsm.jpg?v=1761658082"},{"product_id":"warmup-snow-and-ice-melting-cable-43-72-sq-ft-wsm","title":"Warmup Snow and Ice Melting Cable WSM 43-72 sq ft 240V","description":"\u003ch4\u003eWarmup Snow and Ice Melting Cable WSM - 43 to 72 sq ft Coverage\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eAvailable Voltage:\u003c\/strong\u003e 240V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSuitable for Installation Under:\u003c\/strong\u003e Asphalt, Concrete, and Pavers\u003c\/p\u003e\n\u003cp\u003eThe Warmup WSM Snow Melting Cable is designed to prevent snow and ice buildup on driveways, walkways, ramps, stairs, parking areas, sidewalks, and other outdoor surfaces. These energy-efficient outdoor heating cables are suitable for installation under concrete, asphalt, or paver systems and provide reliable snow melting performance for residential and commercial applications.\u003c\/p\u003e\n\u003cp\u003eWarmup snow melting cables feature a durable twin-conductor design with a single-point power connection and include a 10-Year manufacturer warranty.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Coverage \u0026amp; Electrical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Length:\u003c\/strong\u003e 168 ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistance:\u003c\/strong\u003e 28.9 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmperage:\u003c\/strong\u003e 8.3 Amps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput:\u003c\/strong\u003e 2000 Watts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoverage at 3\" Spacing:\u003c\/strong\u003e 43 sq ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoverage at 4\" Spacing:\u003c\/strong\u003e 57 sq ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoverage at 5\" Spacing:\u003c\/strong\u003e 72 sq ft\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eKey Advantages\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e16 ft cold lead with single-point connection\u003c\/li\u003e\n\u003cli\u003eSuitable for installation in sand, gravel, concrete, asphalt, or on wire mesh\u003c\/li\u003e\n\u003cli\u003eEnergy-efficient twin-conductor heating cable design\u003c\/li\u003e\n\u003cli\u003eIdeal for heated driveways, ramps, sidewalks, stairs, and walkways\u003c\/li\u003e\n\u003cli\u003eSupports full coverage or tire-track snow melting layouts\u003c\/li\u003e\n\u003cli\u003eDesigned for residential and commercial snow melting applications\u003c\/li\u003e\n\u003cli\u003eCompatible with Warmup snow sensors and automatic controls\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe Warmup WSM heating cable is commonly installed in concrete pours, asphalt driveways, paver walkways, loading areas, and commercial outdoor snow melting systems. Embedded up to 4 inches deep, the cable can be configured for full surface snow melting coverage or vehicle tire-track systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Voltage:\u003c\/strong\u003e 240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat Output:\u003c\/strong\u003e ± 50 Watts per sq ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Construction:\u003c\/strong\u003e Twin-conductor fluoropolymer insulated heating cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Diameter:\u003c\/strong\u003e 1\/4\" (6mm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Exposure Temperature:\u003c\/strong\u003e 464°F (240°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Lead Length:\u003c\/strong\u003e 16.4 ft (5m)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 10-Year Manufacturer Warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications \u0026amp; Installation Information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible Surface Materials\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePavers and masonry surfaces\u003c\/li\u003e\n\u003cli\u003eConcrete slabs and walkways\u003c\/li\u003e\n\u003cli\u003eAsphalt driveways and parking surfaces\u003c\/li\u003e\n\u003cli\u003eOutdoor stairs and ramps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible Base Materials\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCrushed gravel base\u003c\/li\u003e\n\u003cli\u003eSand bed\u003c\/li\u003e\n\u003cli\u003eInsulation boards and sheets\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eRecommended Coverage Depth\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Coverage:\u003c\/strong\u003e 2 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Coverage:\u003c\/strong\u003e 4 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation Under Pavers\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor paver applications, the heating cable should be covered with approximately 2 inches of sand before installing the pavers. Pavers should not exceed 4 inches in thickness.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation Under Asphalt\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe WSM cable can withstand direct asphalt contact for a limited time until the asphalt cools. For asphalt pours exceeding 220°F, apply a 2-inch sand layer above the cable before asphalt placement. Rollers exceeding 2 tons should not be used directly over the heating cable. Hand rolling is strongly recommended.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation Under Concrete\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor concrete installations, ensure the cable is embedded no deeper than 4 inches below the finished surface. Re-mesh or wire mesh is recommended to properly suspend the cable within the slab during the concrete pour.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty \u0026amp; Maintenance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen installed according to Warmup installation guidelines and properly tested throughout installation, the WSM snow melting cable system requires virtually no maintenance during its operational life. The cable is backed by Warmup’s 10-Year manufacturer warranty and protected by the Warmup SAFETYnet installation guarantee.\u003c\/p\u003e\n\u003chr\u003e\n\n\u003cp\u003e\u003cstrong\u003eHelpful Resources\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/do-it-yourself\/warmup-snow-melting-questions-answers\"\u003eWarmup Snow Melting Installation Guide\u003c\/a\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0927\/8839\/2257\/files\/warmup_snow_melting_Installation_instructions.pdf?v=1748782050\"\u003eWarmup Snow Melting Specifications \u0026amp; Installation Instructions PDF\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr\u003e\n\n\u003cp\u003e\u003cstrong\u003eRelated Collections\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/warmup-snow-melt\"\u003eShop All Warmup Snow Melting Systems\u003c\/a\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003ca href=\"\/collections\/warmup-heating-mats\"\u003eShop Warmup Snow Melting Mats\u003c\/a\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003ca href=\"\/collections\/warmup-heating-cables\"\u003eShop Warmup Snow Melting Cables\u003c\/a\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003ca href=\"\/collections\/warmup-thermostats-accessories\"\u003eShop Warmup Thermostats \u0026amp; Accessories\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Warmup","offers":[{"title":"Default Title","offer_id":50538554917185,"sku":"WSM-240-2000","price":390.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0927\/8839\/2257\/files\/warmup_snow_melting_cable_wsm.jpg?v=1761658082"},{"product_id":"warmup-snow-and-ice-melting-cable-62-104-sq-ft-wsm","title":"Warmup Snow and Ice Melting Cable WSM 62-104 sq ft 240V","description":"\u003ch4\u003eWarmup Snow and Ice Melting Cable WSM - 62 to 104 sq ft Coverage\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eAvailable Voltage:\u003c\/strong\u003e 240V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSuitable for Installation Under:\u003c\/strong\u003e Asphalt, Concrete, and Pavers\u003c\/p\u003e\n\u003cp\u003eThe Warmup WSM Snow Melting Cable is designed to prevent snow and ice buildup on driveways, walkways, ramps, stairs, parking areas, sidewalks, and other outdoor surfaces. These energy-efficient outdoor heating cables are suitable for installation under concrete, asphalt, or paver systems and provide reliable snow melting performance for residential and commercial applications.\u003c\/p\u003e\n\u003cp\u003eWarmup snow melting cables feature a durable twin-conductor design with a single-point power connection and include a 10-Year manufacturer warranty.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Coverage \u0026amp; Electrical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Length:\u003c\/strong\u003e 251 ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistance:\u003c\/strong\u003e 19.2 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmperage:\u003c\/strong\u003e 12.5 Amps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput:\u003c\/strong\u003e 3000 Watts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoverage at 3\" Spacing:\u003c\/strong\u003e 62 sq ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoverage at 4\" Spacing:\u003c\/strong\u003e 84 sq ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoverage at 5\" Spacing:\u003c\/strong\u003e 104 sq ft\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eKey Advantages\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e16 ft cold lead with single-point connection\u003c\/li\u003e\n\u003cli\u003eSuitable for installation in sand, gravel, concrete, asphalt, or on wire mesh\u003c\/li\u003e\n\u003cli\u003eEnergy-efficient twin-conductor heating cable design\u003c\/li\u003e\n\u003cli\u003eIdeal for heated driveways, ramps, sidewalks, stairs, and walkways\u003c\/li\u003e\n\u003cli\u003eSupports full coverage or tire-track snow melting layouts\u003c\/li\u003e\n\u003cli\u003eDesigned for residential and commercial snow melting applications\u003c\/li\u003e\n\u003cli\u003eCompatible with Warmup snow sensors and automatic controls\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe Warmup WSM heating cable is commonly installed in concrete pours, asphalt driveways, paver walkways, loading areas, and commercial outdoor snow melting systems. Embedded up to 4 inches deep, the cable can be configured for full surface snow melting coverage or vehicle tire-track systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Voltage:\u003c\/strong\u003e 240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat Output:\u003c\/strong\u003e ± 50 Watts per sq ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Construction:\u003c\/strong\u003e Twin-conductor fluoropolymer insulated heating cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Diameter:\u003c\/strong\u003e 1\/4\" (6mm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Exposure Temperature:\u003c\/strong\u003e 464°F (240°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Lead Length:\u003c\/strong\u003e 16.4 ft (5m)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 10-Year Manufacturer Warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications \u0026amp; Installation Information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible Surface Materials\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePavers and masonry surfaces\u003c\/li\u003e\n\u003cli\u003eConcrete slabs and walkways\u003c\/li\u003e\n\u003cli\u003eAsphalt driveways and parking surfaces\u003c\/li\u003e\n\u003cli\u003eOutdoor stairs and ramps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible Base Materials\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCrushed gravel base\u003c\/li\u003e\n\u003cli\u003eSand bed\u003c\/li\u003e\n\u003cli\u003eInsulation boards and sheets\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eRecommended Coverage Depth\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Coverage:\u003c\/strong\u003e 2 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Coverage:\u003c\/strong\u003e 4 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation Under Pavers\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor paver applications, the heating cable should be covered with approximately 2 inches of sand before installing the pavers. Pavers should not exceed 4 inches in thickness.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation Under Asphalt\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe WSM cable can withstand direct asphalt contact for a limited time until the asphalt cools. For asphalt pours exceeding 220°F, apply a 2-inch sand layer above the cable before asphalt placement. Rollers exceeding 2 tons should not be used directly over the heating cable. Hand rolling is strongly recommended.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation Under Concrete\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor concrete installations, ensure the cable is embedded no deeper than 4 inches below the finished surface. Re-mesh or wire mesh is recommended to properly suspend the cable within the slab during the concrete pour.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty \u0026amp; Maintenance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen installed according to Warmup installation guidelines and properly tested throughout installation, the WSM snow melting cable system requires virtually no maintenance during its operational life. The cable is backed by Warmup’s 10-Year manufacturer warranty and protected by the Warmup SAFETYnet installation guarantee.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eHelpful Resources\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/do-it-yourself\/warmup-snow-melting-questions-answers\"\u003eWarmup Snow Melting Installation Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0927\/8839\/2257\/files\/warmup_snow_melting_Installation_instructions.pdf?v=1748782050\"\u003eWarmup Snow Melting Specifications \u0026amp; Installation Instructions PDF\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eRelated Collections\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/warmup-snow-melt\"\u003eShop All Warmup Snow Melting Systems\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/warmup-heating-mats\"\u003eShop Warmup Snow Melting Mats\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/warmup-heating-cables\"\u003eShop Warmup Snow Melting Cables\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/warmup-thermostats-accessories\"\u003eShop Warmup Thermostats \u0026amp; Accessories\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Warmup","offers":[{"title":"Default Title","offer_id":50538556621121,"sku":"WSM-240-3000","price":539.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0927\/8839\/2257\/files\/warmup_snow_melting_cable_wsm.jpg?v=1761658082"},{"product_id":"warmup-snow-and-ice-melting-cable-51-84-sq-ft-wsm","title":"Warmup Snow and Ice Melting Cable WSM 51-84 sq ft 240V\/480V","description":"\u003ch4\u003eWarmup Snow and Ice Melting Cable WSM - 51 to 84 sq ft Coverage\u003c\/h4\u003e\n\n\u003cp\u003e\u003cstrong\u003eAvailable Voltage:\u003c\/strong\u003e 240V \u0026amp; 480V\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eSuitable for Installation Under:\u003c\/strong\u003e Asphalt, Concrete, and Pavers\u003c\/p\u003e\n\n\u003cp\u003eThe Warmup WSM Snow Melting Cable is designed to prevent snow and ice buildup on driveways, walkways, ramps, stairs, parking areas, sidewalks, and other outdoor surfaces. These energy-efficient outdoor heating cables are suitable for installation under concrete, asphalt, or paver systems and provide reliable snow melting performance for residential and commercial applications.\u003c\/p\u003e\n\n\u003cp\u003eWarmup snow melting cables feature a durable twin-conductor design with a single-point power connection and include a 10-Year manufacturer warranty.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCable Coverage \u0026amp; Electrical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e240V Model\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Length:\u003c\/strong\u003e 209 ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistance:\u003c\/strong\u003e 23.1 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmperage:\u003c\/strong\u003e 10.4 Amps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput:\u003c\/strong\u003e 2500 Watts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoverage at 3\" Spacing:\u003c\/strong\u003e 51 sq ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoverage at 4\" Spacing:\u003c\/strong\u003e 67 sq ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoverage at 5\" Spacing:\u003c\/strong\u003e 84 sq ft\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003e480V Model\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Length:\u003c\/strong\u003e 209 ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistance:\u003c\/strong\u003e 92.30 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmperage:\u003c\/strong\u003e 5.20 Amps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput:\u003c\/strong\u003e 2500 Watts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoverage at 3\" Spacing:\u003c\/strong\u003e 51 sq ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoverage at 4\" Spacing:\u003c\/strong\u003e 67 sq ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoverage at 5\" Spacing:\u003c\/strong\u003e 84 sq ft\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eKey Advantages\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e16 ft cold lead with single-point connection\u003c\/li\u003e\n\u003cli\u003eSuitable for installation in sand, gravel, concrete, asphalt, or on wire mesh\u003c\/li\u003e\n\u003cli\u003eEnergy-efficient twin-conductor heating cable design\u003c\/li\u003e\n\u003cli\u003eIdeal for heated driveways, ramps, sidewalks, stairs, and walkways\u003c\/li\u003e\n\u003cli\u003eSupports full coverage or tire-track snow melting layouts\u003c\/li\u003e\n\u003cli\u003eDesigned for residential and commercial snow melting applications\u003c\/li\u003e\n\u003cli\u003eCompatible with Warmup snow sensors and automatic controls\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe Warmup WSM heating cable is commonly installed in concrete pours, asphalt driveways, paver walkways, loading areas, and commercial outdoor snow melting systems. Embedded up to 4 inches deep, the cable can be configured for full surface snow melting coverage or vehicle tire-track systems.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eProduct Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Voltage:\u003c\/strong\u003e 240V \u0026amp; 480V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat Output:\u003c\/strong\u003e ± 50 Watts per sq ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Construction:\u003c\/strong\u003e Twin-conductor fluoropolymer insulated heating cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Diameter:\u003c\/strong\u003e 1\/4\" (6mm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Exposure Temperature:\u003c\/strong\u003e 464°F (240°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Lead Length:\u003c\/strong\u003e 16.4 ft (5m)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 10-Year Manufacturer Warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eApplications \u0026amp; Installation Information\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCompatible Surface Materials\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003ePavers and masonry surfaces\u003c\/li\u003e\n\u003cli\u003eConcrete slabs and walkways\u003c\/li\u003e\n\u003cli\u003eAsphalt driveways and parking surfaces\u003c\/li\u003e\n\u003cli\u003eOutdoor stairs and ramps\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eCompatible Base Materials\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eCrushed gravel base\u003c\/li\u003e\n\u003cli\u003eSand bed\u003c\/li\u003e\n\u003cli\u003eInsulation boards and sheets\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eRecommended Coverage Depth\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Coverage:\u003c\/strong\u003e 2 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Coverage:\u003c\/strong\u003e 4 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eInstallation Under Pavers\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eFor paver applications, the heating cable should be covered with approximately 2 inches of sand before installing the pavers. Pavers should not exceed 4 inches in thickness.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eInstallation Under Asphalt\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe WSM cable can withstand direct asphalt contact for a limited time until the asphalt cools. For asphalt pours exceeding 220°F, apply a 2-inch sand layer above the cable before asphalt placement. Rollers exceeding 2 tons should not be used directly over the heating cable. Hand rolling is strongly recommended.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eInstallation Under Concrete\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eFor concrete installations, ensure the cable is embedded no deeper than 4 inches below the finished surface. Re-mesh or wire mesh is recommended to properly suspend the cable within the slab during the concrete pour.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWarranty \u0026amp; Maintenance\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eWhen installed according to Warmup installation guidelines and properly tested throughout installation, the WSM snow melting cable system requires virtually no maintenance during its operational life. The cable is backed by Warmup’s 10-Year manufacturer warranty and protected by the Warmup SAFETYnet installation guarantee.\u003c\/p\u003e\n\n\u003chr\u003e\n\n\u003cp\u003e\u003cstrong\u003eHelpful Resources\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/do-it-yourself\/warmup-snow-melting-questions-answers\"\u003eWarmup Snow Melting Installation Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0927\/8839\/2257\/files\/warmup_snow_melting_Installation_instructions.pdf?v=1748782050\"\u003eWarmup Snow Melting Specifications \u0026amp; Installation Instructions PDF\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr\u003e\n\n\u003cp\u003e\u003cstrong\u003eRelated Collections\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/warmup-snow-melt\"\u003eShop All Warmup Snow Melting Systems\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/warmup-heating-mats\"\u003eShop Warmup Snow Melting Mats\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/warmup-heating-cables\"\u003eShop Warmup Snow Melting Cables\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/warmup-thermostats-accessories\"\u003eShop Warmup Thermostats \u0026amp; Accessories\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Warmup","offers":[{"title":"240 Volt","offer_id":50492113125697,"sku":"WSM-240-2500-240-volt","price":499.0,"currency_code":"USD","in_stock":true},{"title":"480 Volt","offer_id":50492113158465,"sku":"WSM-240-2500-480-volt","price":525.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0927\/8839\/2257\/files\/warmup_snow_melting_cable_wsm.jpg?v=1761658082"},{"product_id":"warmup-snow-and-ice-melting-cable-100-170-sq-ft-wsm","title":"Warmup Snow and Ice Melting Cable WSM 100-170 sq ft 240V","description":"\u003ch4\u003eWarmup Snow and Ice Melting Cable WSM – 100 to 170 sq ft Coverage\u003c\/h4\u003e\n\n\u003cp\u003e\u003cstrong\u003eAvailable Voltage:\u003c\/strong\u003e 240V\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eSuitable for Installation Under:\u003c\/strong\u003e Asphalt, Concrete, and Pavers\u003c\/p\u003e\n\n\u003cp\u003eThe Warmup WSM Snow Melting Cable is designed to prevent snow and ice buildup on driveways, walkways, ramps, stairs, parking areas, sidewalks, and other outdoor surfaces. These energy-efficient outdoor heating cables are suitable for installation under concrete, asphalt, or paver systems and provide reliable snow melting performance for residential and commercial applications.\u003c\/p\u003e\n\n\u003cp\u003eWarmup snow melting cables feature a durable twin-conductor design with a single-point power connection and include a 10-Year manufacturer warranty.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCable Coverage \u0026amp; Electrical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Length:\u003c\/strong\u003e 420 ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistance:\u003c\/strong\u003e 10.5 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmperage:\u003c\/strong\u003e 20.8 Amps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput:\u003c\/strong\u003e 5000 Watts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoverage at 3\" Spacing:\u003c\/strong\u003e 100 sq ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoverage at 4\" Spacing:\u003c\/strong\u003e 140 sq ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoverage at 5\" Spacing:\u003c\/strong\u003e 170 sq ft\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eKey Advantages\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e16 ft cold lead with single-point connection\u003c\/li\u003e\n\u003cli\u003eSuitable for installation in sand, gravel, concrete, asphalt, or on wire mesh\u003c\/li\u003e\n\u003cli\u003eEnergy-efficient twin-conductor heating cable design\u003c\/li\u003e\n\u003cli\u003eIdeal for heated driveways, ramps, sidewalks, stairs, and walkways\u003c\/li\u003e\n\u003cli\u003eSupports full coverage or tire-track snow melting layouts\u003c\/li\u003e\n\u003cli\u003eDesigned for residential and commercial snow melting applications\u003c\/li\u003e\n\u003cli\u003eCompatible with Warmup snow sensors and automatic controls\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe Warmup WSM heating cable is commonly installed in concrete pours, asphalt driveways, paver walkways, loading areas, and commercial outdoor snow melting systems. Embedded up to 4 inches deep, the cable can be configured for full surface snow melting coverage or vehicle tire-track systems.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eProduct Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Voltage:\u003c\/strong\u003e 240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat Output:\u003c\/strong\u003e ± 50 Watts per sq ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Construction:\u003c\/strong\u003e Twin-conductor fluoropolymer insulated heating cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Diameter:\u003c\/strong\u003e 1\/4\" (6mm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Exposure Temperature:\u003c\/strong\u003e 464°F (240°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Lead Length:\u003c\/strong\u003e 16.4 ft (5m)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 10-Year Manufacturer Warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eApplications \u0026amp; Installation Information\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCompatible Surface Materials\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003ePavers and masonry surfaces\u003c\/li\u003e\n\u003cli\u003eConcrete slabs and walkways\u003c\/li\u003e\n\u003cli\u003eAsphalt driveways and parking surfaces\u003c\/li\u003e\n\u003cli\u003eOutdoor stairs and ramps\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eCompatible Base Materials\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eCrushed gravel base\u003c\/li\u003e\n\u003cli\u003eSand bed\u003c\/li\u003e\n\u003cli\u003eInsulation boards and sheets\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eRecommended Coverage Depth\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Coverage:\u003c\/strong\u003e 2 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Coverage:\u003c\/strong\u003e 4 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eInstallation Under Pavers\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eFor paver applications, the heating cable should be covered with approximately 2 inches of sand before installing the pavers. Pavers should not exceed 4 inches in thickness.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eInstallation Under Asphalt\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe WSM cable can withstand direct asphalt contact for a limited time until the asphalt cools. For asphalt pours exceeding 220°F, apply a 2-inch sand layer above the cable before asphalt placement. Rollers exceeding 2 tons should not be used directly over the heating cable. Hand rolling is strongly recommended.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eInstallation Under Concrete\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eFor concrete installations, ensure the cable is embedded no deeper than 4 inches below the finished surface. Re-mesh or wire mesh is recommended to properly suspend the cable within the slab during the concrete pour.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWarranty \u0026amp; Maintenance\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eWhen installed according to Warmup installation guidelines and properly tested throughout installation, the WSM snow melting cable system requires virtually no maintenance during its operational life. The cable is backed by Warmup’s 10-Year manufacturer warranty and protected by the Warmup SAFETYnet installation guarantee.\u003c\/p\u003e\n\n\u003chr\u003e\n\n\u003cp\u003e\u003cstrong\u003eHelpful Resources\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/do-it-yourself\/warmup-snow-melting-questions-answers\"\u003eWarmup Snow Melting Installation Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0927\/8839\/2257\/files\/warmup_snow_melting_Installation_instructions.pdf?v=1748782050\"\u003eWarmup Snow Melting Specifications \u0026amp; Installation Instructions PDF\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr\u003e\n\n\u003cp\u003e\u003cstrong\u003eRelated Collections\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/warmup-snow-melt\"\u003eShop All Warmup Snow Melting Systems\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/warmup-heating-mats\"\u003eShop Warmup Snow Melting Mats\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/warmup-heating-cables\"\u003eShop Warmup Snow Melting Cables\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/warmup-thermostats-accessories\"\u003eShop Warmup Thermostats \u0026amp; Accessories\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Warmup","offers":[{"title":"Default Title","offer_id":50538564387137,"sku":"WSM-240-5000","price":859.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0927\/8839\/2257\/files\/warmup_snow_melting_cable_wsm.jpg?v=1761658082"},{"product_id":"warmup-snow-and-ice-melting-cable-85-135-sq-ft-wsm","title":"Warmup Snow and Ice Melting Cable WSM 85-135 sq ft 240V\/480V","description":"\u003ch4\u003eWarmup Snow and Ice Melting Cable WSM - 85 to 135 sq ft Coverage\u003c\/h4\u003e\n\n\u003cp\u003e\u003cstrong\u003eAvailable Voltage:\u003c\/strong\u003e 240V \u0026amp; 480V\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eSuitable for Installation Under:\u003c\/strong\u003e Asphalt, Concrete, and Pavers\u003c\/p\u003e\n\n\u003cp\u003eThe Warmup WSM Snow Melting Cable is designed to prevent snow and ice buildup on driveways, walkways, ramps, stairs, parking areas, sidewalks, and other outdoor surfaces. These energy-efficient outdoor heating cables are suitable for installation under concrete, asphalt, or paver systems and provide reliable snow melting performance for residential and commercial applications.\u003c\/p\u003e\n\n\u003cp\u003eWarmup snow melting cables feature a durable twin-conductor design with a single-point power connection and include a 10-Year manufacturer warranty.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCable Coverage \u0026amp; Electrical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e240V Model\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Length:\u003c\/strong\u003e 342.2 ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistance:\u003c\/strong\u003e 11.5 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmperage:\u003c\/strong\u003e 16.7 Amps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput:\u003c\/strong\u003e 4000 Watts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoverage at 3\" Spacing:\u003c\/strong\u003e 85 sq ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoverage at 4\" Spacing:\u003c\/strong\u003e 110 sq ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoverage at 5\" Spacing:\u003c\/strong\u003e 135 sq ft\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003e480V Model\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Length:\u003c\/strong\u003e 342.2 ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistance:\u003c\/strong\u003e 57.22 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmperage:\u003c\/strong\u003e 8.33 Amps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput:\u003c\/strong\u003e 4000 Watts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoverage at 3\" Spacing:\u003c\/strong\u003e 85 sq ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoverage at 4\" Spacing:\u003c\/strong\u003e 110 sq ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoverage at 5\" Spacing:\u003c\/strong\u003e 135 sq ft\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eKey Advantages\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e16 ft cold lead with single-point connection\u003c\/li\u003e\n\u003cli\u003eSuitable for installation in sand, gravel, concrete, asphalt, or on wire mesh\u003c\/li\u003e\n\u003cli\u003eEnergy-efficient twin-conductor heating cable design\u003c\/li\u003e\n\u003cli\u003eIdeal for heated driveways, ramps, sidewalks, stairs, and walkways\u003c\/li\u003e\n\u003cli\u003eSupports full coverage or tire-track snow melting layouts\u003c\/li\u003e\n\u003cli\u003eDesigned for residential and commercial snow melting applications\u003c\/li\u003e\n\u003cli\u003eCompatible with Warmup snow sensors and automatic controls\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe Warmup WSM heating cable is commonly installed in concrete pours, asphalt driveways, paver walkways, loading areas, and commercial outdoor snow melting systems. Embedded up to 4 inches deep, the cable can be configured for full surface snow melting coverage or vehicle tire-track systems.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eProduct Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Voltage:\u003c\/strong\u003e 240V \u0026amp; 480V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat Output:\u003c\/strong\u003e ± 50 Watts per sq ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Construction:\u003c\/strong\u003e Twin-conductor fluoropolymer insulated heating cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Diameter:\u003c\/strong\u003e 1\/4\" (6mm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Exposure Temperature:\u003c\/strong\u003e 464°F (240°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Lead Length:\u003c\/strong\u003e 16.4 ft (5m)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 10-Year Manufacturer Warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eApplications \u0026amp; Installation Information\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCompatible Surface Materials\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003ePavers and masonry surfaces\u003c\/li\u003e\n\u003cli\u003eConcrete slabs and walkways\u003c\/li\u003e\n\u003cli\u003eAsphalt driveways and parking surfaces\u003c\/li\u003e\n\u003cli\u003eOutdoor stairs and ramps\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eCompatible Base Materials\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eCrushed gravel base\u003c\/li\u003e\n\u003cli\u003eSand bed\u003c\/li\u003e\n\u003cli\u003eInsulation boards and sheets\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eRecommended Coverage Depth\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Coverage:\u003c\/strong\u003e 2 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Coverage:\u003c\/strong\u003e 4 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eInstallation Under Pavers\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eFor paver applications, the heating cable should be covered with approximately 2 inches of sand before installing the pavers. Pavers should not exceed 4 inches in thickness.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eInstallation Under Asphalt\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe WSM cable can withstand direct asphalt contact for a limited time until the asphalt cools. For asphalt pours exceeding 220°F, apply a 2-inch sand layer above the cable before asphalt placement. Rollers exceeding 2 tons should not be used directly over the heating cable. Hand rolling is strongly recommended.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eInstallation Under Concrete\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eFor concrete installations, ensure the cable is embedded no deeper than 4 inches below the finished surface. Re-mesh or wire mesh is recommended to properly suspend the cable within the slab during the concrete pour.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWarranty \u0026amp; Maintenance\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eWhen installed according to Warmup installation guidelines and properly tested throughout installation, the WSM snow melting cable system requires virtually no maintenance during its operational life. The cable is backed by Warmup’s 10-Year manufacturer warranty and protected by the Warmup SAFETYnet installation guarantee.\u003c\/p\u003e\n\n\u003chr\u003e\n\n\u003cp\u003e\u003cstrong\u003eHelpful Resources\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/do-it-yourself\/warmup-snow-melting-questions-answers\"\u003eWarmup Snow Melting Installation Guide\u003c\/a\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0927\/8839\/2257\/files\/warmup_snow_melting_Installation_instructions.pdf?v=1748782050\"\u003eWarmup Snow Melting Specifications \u0026amp; Installation Instructions PDF\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr\u003e\n\n\u003cp\u003e\u003cstrong\u003eRelated Collections\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/warmup-snow-melt\"\u003eShop All Warmup Snow Melting Systems\u003c\/a\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003ca href=\"\/collections\/warmup-heating-mats\"\u003eShop Warmup Snow Melting Mats\u003c\/a\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003ca href=\"\/collections\/warmup-heating-cables\"\u003eShop Warmup Snow Melting Cables\u003c\/a\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003ca href=\"\/collections\/warmup-thermostats-accessories\"\u003eShop Warmup Thermostats \u0026amp; Accessories\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Warmup","offers":[{"title":"240 Volt","offer_id":50492114862401,"sku":"WSM-240-4000-240-volt","price":709.0,"currency_code":"USD","in_stock":true},{"title":"480 Volt","offer_id":50492114895169,"sku":"WSM-240-4000-480-volt","price":746.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0927\/8839\/2257\/files\/warmup_snow_melting_cable_wsm.jpg?v=1761658082"},{"product_id":"warmup-snow-and-ice-melting-cable-122-200-sq-ft-wsm","title":"Warmup Snow and Ice Melting Cable WSM 122-200 sq ft 240V","description":"\u003ch4\u003eWarmup Snow and Ice Melting Cable WSM - 122 to 200 sq ft Coverage\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eAvailable Voltage:\u003c\/strong\u003e 240V \u0026amp; 480V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSuitable for Installation Under:\u003c\/strong\u003e Asphalt, Concrete, and Pavers\u003c\/p\u003e\n\u003cp\u003eThe Warmup WSM Snow Melting Cable is designed to prevent snow and ice buildup on driveways, walkways, ramps, stairs, parking areas, sidewalks, and other outdoor surfaces. These energy-efficient outdoor heating cables are suitable for installation under concrete, asphalt, or paver systems and provide reliable snow melting performance for both residential and commercial applications.\u003c\/p\u003e\n\u003cp\u003eWarmup snow melting cables feature a durable twin-conductor design with a single-point power connection and include a 10-Year manufacturer warranty.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Coverage \u0026amp; Electrical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e240V Model\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Length:\u003c\/strong\u003e 500 ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistance:\u003c\/strong\u003e 9.6 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmperage:\u003c\/strong\u003e 25.0 Amps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput:\u003c\/strong\u003e 6000 Watts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoverage at 3\" Spacing:\u003c\/strong\u003e 122 sq ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoverage at 4\" Spacing:\u003c\/strong\u003e 181 sq ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoverage at 5\" Spacing:\u003c\/strong\u003e 200 sq ft\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e480V Model\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Length:\u003c\/strong\u003e 500 ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistance:\u003c\/strong\u003e 46.15 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmperage:\u003c\/strong\u003e 10.4 Amps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput:\u003c\/strong\u003e 6000 Watts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoverage at 3\" Spacing:\u003c\/strong\u003e 122 sq ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoverage at 4\" Spacing:\u003c\/strong\u003e 181 sq ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoverage at 5\" Spacing:\u003c\/strong\u003e 200 sq ft\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eKey Advantages\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e16 ft cold lead with single-point connection\u003c\/li\u003e\n\u003cli\u003eSuitable for installation in sand, gravel, concrete, asphalt, or on wire mesh\u003c\/li\u003e\n\u003cli\u003eEnergy-efficient twin-conductor heating cable design\u003c\/li\u003e\n\u003cli\u003eIdeal for heated driveways, ramps, sidewalks, stairs, and walkways\u003c\/li\u003e\n\u003cli\u003eSupports full coverage or tire-track snow melting layouts\u003c\/li\u003e\n\u003cli\u003eDesigned for residential and commercial snow melting applications\u003c\/li\u003e\n\u003cli\u003eCompatible with Warmup snow sensors and automatic controls\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe Warmup WSM heating cable is commonly installed in concrete pours, asphalt driveways, paver walkways, loading areas, and commercial outdoor snow melting systems. Embedded up to 4 inches deep, the cable can be configured for full surface snow melting coverage or vehicle tire-track systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Voltage:\u003c\/strong\u003e 240V \u0026amp; 480V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat Output:\u003c\/strong\u003e ± 50 Watts per sq ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Length Range:\u003c\/strong\u003e 84 ft (25m) to 500 ft (152m)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Construction:\u003c\/strong\u003e Twin-conductor fluoropolymer insulated heating cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Diameter:\u003c\/strong\u003e 1\/4\" (6mm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Exposure Temperature:\u003c\/strong\u003e 464°F (240°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Lead Length:\u003c\/strong\u003e 16.4 ft (5m)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 10-Year Manufacturer Warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications \u0026amp; Installation Information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible Surface Materials\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePavers and masonry surfaces\u003c\/li\u003e\n\u003cli\u003eConcrete slabs and walkways\u003c\/li\u003e\n\u003cli\u003eAsphalt driveways and parking surfaces\u003c\/li\u003e\n\u003cli\u003eOutdoor stairs and ramps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible Base Materials\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCrushed gravel base\u003c\/li\u003e\n\u003cli\u003eSand bed\u003c\/li\u003e\n\u003cli\u003eInsulation boards and sheets\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eRecommended Coverage Depth\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Coverage:\u003c\/strong\u003e 2 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Coverage:\u003c\/strong\u003e 4 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation Under Pavers\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor paver applications, the heating cable should be covered with approximately 2 inches of sand before installing the pavers. Pavers should not exceed 4 inches in thickness.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation Under Asphalt\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe WSM cable can withstand direct asphalt contact for a limited time until the asphalt cools. For asphalt pours exceeding 220°F, apply a 2-inch sand layer above the cable before asphalt placement. Rollers exceeding 2 tons should not be used directly over the heating cable. Hand rolling is strongly recommended.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation Under Concrete\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor concrete installations, ensure the cable is embedded no deeper than 4 inches below the finished surface. Re-mesh or wire mesh is recommended to properly suspend the cable within the slab during the concrete pour.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty \u0026amp; Maintenance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen installed according to Warmup installation guidelines and properly tested throughout installation, the WSM snow melting cable system requires virtually no maintenance during its operational life. The cable is backed by Warmup’s 10-Year manufacturer warranty and protected by the Warmup SAFETYnet installation guarantee.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eHelpful Resources\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/do-it-yourself\/warmup-snow-melting-questions-answers\"\u003eWarmup Snow Melting Installation Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0927\/8839\/2257\/files\/warmup_snow_melting_Installation_instructions.pdf?v=1748782050\"\u003eWarmup Snow Melting Specifications \u0026amp; Installation Instructions PDF\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eRelated Collections\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/warmup-snow-melt\"\u003eShop All Warmup Snow Melting Systems\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/warmup-heating-mats\"\u003eShop Warmup Snow Melting Mats\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/warmup-heating-cables\"\u003eShop Warmup Snow Melting Cables\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/warmup-thermostats-accessories\"\u003eShop Warmup Thermostats \u0026amp; Accessories\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Warmup","offers":[{"title":"240 Volt","offer_id":50492115386689,"sku":"WSM-240-6000-240-volt","price":1019.0,"currency_code":"USD","in_stock":true},{"title":"480 Volt","offer_id":50492115419457,"sku":"WSM-240-6000-480-volt","price":1045.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0927\/8839\/2257\/files\/warmup_snow_melting_cable_wsm.jpg?v=1761658082"}],"url":"https:\/\/flooringsupplyshop.com\/collections\/warmup-snow-melt-cables.oembed","provider":"Flooring Supply Shop","version":"1.0","type":"link"}