Installation Guide Non Programmable SunStat Control
By SunTouch® A division of Watts Water Technologies, Inc.
Installation Guide
Review
For the smaller Spot Warming mats, we recommend the SunStat control.
This device uses a floor sensor to maintain the precise temperature you select for your tile.
You can pick a normal setting or push a button to select a “setback” or night time usage to ensure your floor tiles stay warm. Each radiant floor heating mat control includes a built-in GFCI (Ground Fault Circuit Interrupter) for your safety
Dual Voltage for both 120 VAC and 240 VAC
The non-programmable FloorStat is very simple to operate. Simply slide the on/off switch and turn the dial to set the floor temperature. Other features include a floor sensor that directly senses floor temperature; built-in ground
fault protection with no need for a separate GFCI (in most code areas); temperature range of 59° to 95°F; 15-amp
capacity to control up to 150 sq. ft. of 120-VAC SunTouch mats. Available only in 120 VAC model.
Features include a floor sensor that directly senses floor temperature, 15-amp capacity controlling up to 150 sq. ft. of 120-VAC mats or 300 sq. ft. of 240-VAC mats; built-in ground fault protection with no need for a separate GFCI (in most code areas) large, back-lit digital display
temperature range of 40° to 104°F.
Temperature display in °F or °C; on/off switch; 12 or 24-hr. clock.
Specifications – 500675
Programmable Control Model 500675
|
Power Supply
|
120/240 VAC 50/60 Hz
|
Maximum Load
|
15 amps, resistive
|
Maximum Power
|
1800 watts at 120 VAC 3600 watts at240 VAC |
GFCI Class
|
(5 millamp trip)
|
Display Range
|
32F to 140F (0 C to 60 C)
|
Setting Range
|
40F to 99F (4 C to 37 C)
|
Accuracy
|
+ 0.9 F (0.5 C)
|
Storage Temp
|
0 F to 120 F (0 C to 49 C)
|
Memory
|
Setting Retained Indefinitely
|
ETL Listing
|
Control No. 3037530
|
Material
• One (1) power base
• Two (2) 6-32 screws 1-1/4 in.
• Four (4) solder less connectors for copper wires
NOTE: Special CO/ALR solder less connectors must be used when connecting with aluminum conductors.
• One (1) temperature sensor with a 15-ft. (4.5-meter) extension
• One (1) flat-tip screwdriver.
Installation Guidelines
Turn off power to the heating system at the main power panel to avoid electrical shock.
Keep the SunStat’s air vents clean and free from obstructions. Installation should be carried out by electricians or experienced technicians.
• High voltage SunStat must be installed onto an electrical box.
• For a new installation, choose a location about 5 ft. (approximately 1.5 meters) above the floor, with good air circulation.
• The SunStat must be installed facing the heating system.
• The SunrStat must be installed on an inside wall.
• Avoid locations where there are air drafts (top of staircase, air outlet), dead air spots (behind a door), direct sunlight or concealed chimneys or stove pipes.
Installation Steps
The GFCI monitors electricity flow for any loss of current; if there is, the
SunStat immediately cuts power to the heating system.
We recommend
you test the GFCI right after installing the control module, and once a
month thereafter to ensure it is operating properly.
To test
1. Press the TEST button:
• Successful: Test warning light is ON and power to heating system is cut-off.
• Unsuccessful: Test warning light is OFF. Cut power to heating system from the main
power panel and call technical service.
2. When successful, reset FloorStat (On/Standby)to power the heating system.
NOTE: If the warning light comes on during normal operation, cut power to heating system from the main power panel and have an electrician verify the installation.
Dimensions
Face Size
|
Overall Size
|
Width : 2 7/8″
|
Width : 2 7/8″
|
Height : 4 9/16″
|
Height : 4 9/16″
|
Depth : 13/16″
|
Depth : 1 3/4″
|
Technical Specifications – 500675
|
Models: | 500675-120CS (120 VAC) |
Setting range: | 59°F to 95°F (15°C to 35°C); minimum: 45°F (7°C) |
Potentiometers: | Minimum: 41°F to 77°F (5°C to 25°C)
Maximum: 59°F to 95°F (15°C to 35°C) |
Accuracy: | 0.9°F (0.5°C) |
Storage: | -4°F to 120°F (-20°C to 50°C) |
Features and Specifications
|
500670
|
500675
|
500680
|
Dual Voltage 120/240 Volt 50/60 |
X
|
X
|
X
|
Floor Sensing Control |
X
|
X
|
|
Air-Sensing Control Capability |
X
|
X
|
|
Regulator (no sensor) Control |
X
|
X
|
|
SmartSrart Technology |
X
|
X
|
|
“Master” Control Capability |
X
|
X
|
|
Manual Temperature Setback |
X
|
X
|
X
|
Manual On/Off Switch |
X
|
X
|
X
|
Class 2 Insulated Sensor ( 15 Ft. long) |
X
|
X
|
|
Large Backlight Digital Display |
X
|
X
|
|
Keyboard Lockout |
X
|
X
|
|
Remote Control |
X
|
X
|
|
Fahrenheit and Celsius Format |
X
|
X
|
|
12-hour 24-hour clock display |
X
|
X
|
|
15-amp (resistive) Relay output |
X
|
X
|
X
|
Class A (5 milliamp trip) GFCI |
X
|
X
|
X
|
5/1/1 Day Programming |
X
|
||
Four preset Schedules |
X
|
||
One User Set Schedule |
X
|
||
Usage Monitoring |
X
|
||
Display Range ———-32-140F (0-60C) |
X
|
X
|
|
Setting Range ———-40 TO 99 F (4 TO 37C) |
X
|
X
|
|
Programming Retained Indefinitely |
X
|
X
|
|
Listed by ETL for USA and Canada |
X
|
X
|
X
|
Specifications – 500680
FEATURES
• Convenience: controls up to 10 slave units from a single master thermostat. Each Slave Unit can handle up to 15 amps.
• Controls slave units operating on different line voltages.
• Versatility: works with programmable and non-programmable models.
• Floor sensor enables precise control of floor temperature.
• Advanced temperature control ensures total comfort by minimizing temperature variations.
• Battery free.
SunStat Relay Slave Unit 500680
|
Power Supply
|
120/240 VAC 50/60 Hz
|
Maximum Load
|
15 amps, resistive
|
Maximum Power
|
1800 watts at 120 VAC 3600 watts at240 VAC |
GFCI Class
|
(5 millamp trip)
|
Storage Temp
|
0 F to 120 F (0 C to 49 C)
|
ETL Listing
|
Control No. 3037530
|
If a mat or cable system requires more than 15 amps, we recommend installing SunStat Relays.
SunTouch’s new SunStat Relays System is specially designed for large floor heating applications exceeding 15 amps. Here’s how it works:
Relays connect directly to SunStat thermostats for simple, elegant control of larger system.
SunStat Relays don’t require a special “master thermostat”, as before with the older version, this new Relays are dual voltage 120 VAC or 240 VAC, have a 15-amp capacity, and on/off switch and GFCI and test light.
It’s possible to control over 1500 sq. ft. of electric floor warming using 120 VAC and cover 3,000 VAC sq. ft floor warming mats or cables.
SunStat Relay
• Programmable and Non-programmable models available
• Controls up to 10 slave units (120vac & 240vac)
• Low voltage wiring means SunStat Relay can be installed anywhere
• Silent operation
The new SunStat Relays System is specially designed for large floor heating applications exceeding 15 amps. Here’s how it works:
First, find the amp draw for each SunStat, UnderFloor or Warm Wire product on our web site, or on our more information section, then determine how many can connect to each relay. Up to ten 15-amp Relays can connect to one SunStat.
Ten Relays. Plus the internal relay in the SunStat, provide a total capacity of 165 amps! Each Relay should be connected to individual 20 amp breakers, as shown in this page picture
WARRANTY
WATTS RADIANT, INC. ONE (1) YEAR LIMITED WARRANTY
This product is warranted against defects in material and workmanship
occurring during normal use for a period of one year from the date of the
original purchase from authorized dealers.
During this period, Watts
Radiant, Inc. will repair or replace with a new or equivalent quality
product without charge at Watts Radiant, Inc.’s option, any product proven by Watts Radiant, Inc. to be defective in normal use.
Warranty does not cover transportation costs, nor does it cover a product subjected to misuse or accidental damage.
This warranty does not
cover the cost of installation, removal or reinstallation of the product or
associated materials and labor.
This limited warranty is in lieu of all other warranties, obligations or liabilities expressed or implied by the company. In no event shall Watts Radiant, Inc. be liable for consequential or incidental damages resulting from installation of this product.
Some states or provinces do not allow limitations on how long an implied warranty lasts, or the exclusion or limitation of incidental or consequential damages, so the above exclusions or limitations may not apply to you.
This warranty gives you specific legal rights and you may also have other rights which vary from state to state.
The defective product and the original sale receipt must be returned to the us pre-paid and insured to:
International Flooring Center, Inc. / flooringsupplyshop.com.
5047 W Jefferson Blvd
Los Angeles, CA 90016
Click here for SunTouch VIDEO Library
SunTouch vs. Product A – SunTouch vs. Product B
SunTouch Floor Heating Mat Links
SunTouch Mats Spec and installation – SunTouch Mat Specification – Underfloor Spec and Installation
SunTouch Floor Heating Spool Links
SunTouch WarmWire Installation Guidelines – SunTouch WarmWire Strap – WarmWire Installation Guidelines – WarmWire Order Instruction and Information
Heating Controls Links
Programmable SunStat Spec – Owner’s Manual Programmable 500670-SB – Owner Manual Non Programmable 500675
– SunStat Non Programmable Spec – SunStat Relays Control – LoudMouth Operating Instruction
Misc SunTouch Links
SunTouch 25 year Limited Warranty – EMF Electromagnetic fields – Frequently Asked Questions – Repair Heating Wire – Suntouch Low Price Guarantee
The post SunStat Non Programmable Specifications first appeared on Flooring Supply Shop Blog.