Satisfaction guaranteed. Call us anytime at 323-731-8453.
Flooring Supply Shop Blog | Flooring and Floor Heating Supply - Part 15

Announcing the Launch of Our New Website Design

After months of preparation, dedication and hard work to prepare for this exciting day, FlooringSupplyShop is delighted to officially announce the launch our newly designed website. The new site launched on Oct 20th, 2013, and is located at the same address: www.flooringsupplyshop.com
That’s right folks, we took a dose of our own medicine.

At FlooringSupplyShop.com  our goal for the new website is to provide our visitors with an extremely user friendly website. The new innovative site will offer more functionality and easier navigation with more in-depth information about our DIY home improvement products.

The new site is completely fluid, fully responsive and fits all types of browser resolutions. It also has a touch-friendly mobile navigation menu.

So, whether you are “just looking” or you are seeking more specific details about a one of our Ready to Tile Benches to use or maybe seeking more information regarding the difference option building your own shower, we are here to help you learn more as we strive to give the most updated information and offer great learning tools for different types of guests that visit our site.

When you have a few minutes, please review our new site. You will feel the commitment, the passion, and dedication of everyone in the FlooringSupplyShop family. We would appreciate your thoughts on how our efforts have resonated with you.

We hope you like our new website. If you experience any problems using it or if you have any suggestions, please contact us at contact@flooringsupplyshop.com

Composeal Gold and Radiant Heat Flooring Systems

Composeal Gold and Radiant Heat Flooring Systems.

Flexible Crack Isolation Waterproofing and Heat Fused for Floors – Walls – Roof Deck / Terraces – Under “thick bed” Tile Installations

Heat Fused, floor heating underlayment, cork insulation, heating insulation, Composeal Gold, Crack Isolation, composeal blue, Pan Liner, sheet membrane, waterproofing membrane

Buy Now

Many of our customers have been asking us how Radiant Floor Heating Systems should be installed when using COMPOSEAL GOLD. When it comes to installing radiant floor heating, we go through a process called the “installation sandwich.”

As you go through the process of installing Radiant Floor Heating Systems, you can see that the flooring consists of a variety of layers. Like a sandwich, these layers stack on top of one another in order to function properly.

So what is COMPOSEAL GOLD?

COMPOSEAL GOLD is a direct bond membrane made up of a high-density PVC, with non-woven polyester scrim laminated on either side of the 40 mil sheet membrane, for direct bonding to the substrate as well as the ceramic tile or marble above. It does not rot and is highly resistant to solutions containing salts, acids, and alkalis, as well as many organic solvents, alcohols, and oils. COMPOSEAL GOLD is used as a concealed crack isolation (anti-fracture) and/or waterproof membrane under thin-set installations of ceramic tile and marble, terrazzo and brick; for new construction, remodeling or repair, residential and commercial, in kitchens, restaurants, resident entries, steam rooms, radiant heated flooring, shopping malls, etc.

Negligible shrinkage at extreme temperatures, -20° F to 212° F, makes COMPOSEAL GOLD especially ideal for Radiant Heated Flooring Systems. Its scrim is designed specifically for direct bonding on both sides of the “sandwich” in ceramic tile and dimension stone installations. This serves as a Crack-Isolation (uncoupling) membrane that provides adequate support/load distribution for your tile covering, and allows the heat from the system below to radiate up through the installation into the room.

*Always consult with the manufacturer of the radiant heating system for their specific installation instructions for installing radiant heating under ceramic tile.

Step 1: Expose the Subfloor

Remove the old carpet, leaving the subfloor exposed. If necessary, use a scraper to separate the carpet from the floor. Remove excess glue from the cement subfloor with scrapers and an appropriate solvent, making sure to follow the solvent directions.

Step 2: Apply a Crack-Suppression Membrane (COMPOSEAL GOLD)

Following the manufacturer’s instructions, apply adhesive to the concrete subfloor and lay down the crack-suppression membrane. Apply the adhesive in sections and unroll the membrane onto the floor, using a floor roller to press it flat and work out any air bubbles. Since concrete expands and contracts as the temperature changes, this membrane will help support the floor and prevent cracks in the tiles or grout.

Step 3: Install the Grids for the Radiant Heating System

Install the plastic grids that will hold the radiant-heat wires, using hot glue to adhere the grids to the subfloor. Follow the manufacturer’s instructions, and space the grids uniformly over the floor to prevent hot and cool patches.

Step 4: Snap the Cables into the Grids

Snap the radiant-heat cables into the grids, keeping them evenly spaced to prevent hot and cool patches in the floor. Check the manufacturer’s instructions for guidance on how far apart to space the cables.

Step 5: Mix and Spread the Thinset Mortar

Use a heavy-duty drill with a paddle bit to mix Thinset mortar according to the package instructions. Use a straight-edge trowel to apply a layer of mortar over the electrical cables. When mixed to the correct consistency, the mortar will stick and mound on the trowel without falling off. Make sure to hold the trowel at a consistent angle throughout the job so the mortar bed will have a uniform thickness. Allow the mortar to dry thoroughly before proceeding. Wet or cold weather will slow down the drying process, and below-freezing temperatures can keep the mortar from curing properly. Consult the manufacturer’s instructions for guidance.

Step 6: Power the Radiant-Heat Floor

The best way to power the radiant-heat floor is to hire a licensed electrician to run a dedicated circuit from the home’s main electrical panel to the correct room. The electrician also can install the control panel/heating sensor in the wall.

Step 7: Determine the Layout

Dry-fit a vertical row of tiles and a horizontal row, leaving space for grout, to determine the best layout. The ideal layout will use as many full tiles as possible. The tiles against the wall should be a half-tile wide or wider.

Step 8: Spread Mortar and Lay the Tiles

Spread mortar on the floor, using the notched edge of the trowel to create deep grooves in the mortar. Press each tile into the mortar, wiggling it gently to seat it. Check the tiles for level and adjust as needed. Use tile spacers to keep an even grout line. Use a wet saw to cut tiles as needed for the perimeter of the floor.

Safety Alert: Always wear safety glasses and use caution when working with a wet saw.

Step 9: Mix and Apply the Grout, and Apply Sealant

After the mortar is dry, mix the tile grout according to the package instructions and apply with a grout float. Use a diagonal motion to apply the grout, working it into the spaces between the tiles. Let the grout dry slightly, then wipe the excess off the tiles with a damp sponge using a diagonal motion.

Let the grout dry completely before sealing. Once the grout sealant is dry, move the furniture back into the room. Let the mortar cure for four weeks before using the radiant-heat system.

CODES, CERTIFICATION

COMPOSEAL 30 and 40 comply with the three major plumbing codes: UPC-IAPMO, SBCCI and BOCA. COMPOSEAL has separate municipal approval where required, e.g. City of Los Angeles, City of Philadelphia (40 mil), Metropolitan Dade County and Commonwealth of Massachusetts. (Approval is no longer required in New York City for concealed PVC waterproof membrane).

COMPOSEAL also complies with the Corps of Engineers specs for PVC shower pan material (para 5.8.3.2 15 p1-18) and meets the requirements of FHA Publication 4900.1.

WARRANTY: COMPOSEAL 30 and 40 are warranted against failure for any reason, and in the event of failure, replacement material will be supplied at no charge. This warranty applies only to the membrane itself and not to the manner of installation over which we have no control, and it does not extend to consequential damage or other implied responsibility. COMPOSEAL should last the life of the building.

Made in USA – 100% American Labor and Materials.

Composeal Gold Installation Instructions

Composeal Blue Vinyl Shower Pan Membrane How to Install

How to Properly Tile a Roof Deck

roof deck tile design

When installing ceramic tile on roof decks, the most important single thing to remember is that a roof deck is just that, a roof – a barrier against the elements and especially water.

“It’s only a roof deck!” Did you ever hear that statement? When and if you do, be prepared for problems, and very possibly big ones. Where roof decks and concerned, roof is the most important word. When it comes to keeping water out, how the roof deck is constructed is at least as important as the balance of the roof itself, since both must satisfy the same requirement to keep the rooms and equipment below them dry.

SOME BAD EXAMPLES

A roof deck was leaking badly. Upon investigation, it was found that the installation had been made using one of the methods described in the Handbook for Ceramic Tile Installation. Why, then, the leakage? The method selected was one involving a cleavage membrane, and it had been chosen even though some of the other methods contained in the Handbook called for a waterproof membrane. The purpose of the cleavage membrane, as you will recall, is to isolate the tile floor from the structure, not to serve as a waterproof membrane.

Another somewhat similar project was purposely installed over a cleavage membrane consisting of a single layer of roofing paper. Those responsible for the installation thought the horizontal tile were waterproof, and therefore did not need a waterproof membrane. But while ceramic tile floors do not disintegrate when wet, they are not waterproof. A good waterproof membrane like Composeal Gold Crack Isolation Waterproof Membrane  is the only insurance against water damage in the rooms under a roof deck.

Two residences came close to taking the prize for most water damage. Built by the same contractor for two sisters, the houses faced each other, with a street in between them. The houses were already completed, with carpets, furniture and kitchen equipment in place, but before anyone could move in, the rains came – heavy rains. The resulting damage to ceilings, walls, furniture and carpets made the homes impossible to occupy. Much of the water came down in the kitchens, where cabinets were soaked, discolored and warped out of shape. What had happened? Each house had a rear, exterior, second story, tile deck which sloped the wrong way, toward the house, with nothing to prevent the water from going through the metal sill of the large sliding doors and into the structures.

Yet another common shortcoming in deck construction is the improper placement of flashing, or even its complete lack, at the junction of the walls and floor. A number of leaky decks have been found in which the lack of flashing has been the cause of the leakage.

Recently, an owner was having problems with leaks in a tiled deck. It started with leaks in the first deck to be installed; after the first deck was replaced, the new deck also leaked. The owner called for advice on how to make sure a third deck would not leak. She was advised on how the deck should be constructed, and was also urged to water – test the Composeal Gold Waterproof Membrane before installing the ceramic tile. The water test had to be stopped immediately because of the torrent of water that flowed into the room below. It is hard to understand how workmen can be so careless or lacking in knowledge as to allow such a membrane to be water- tested. The roofer had terminated the waterproof membrane *” short of membering up with the roofed-over part of structure, and the builder had done nothing to flash and waterproof that joint prior to the water test.

SLOPE ON STRUCTURE

In 1956, working with the International Association of Plumbing and Mechanical Officials, sponsors and authors of the Uniform Plumbing Code, tiled shower floor receptors were at last properly engineered and made part of the Uniform Plumbing Code.

The important part of this engineering called for pre-sloping the floor of the shower prior to placement of the waterproof membrane. The waterproof membrane was then placed in the pre-sloped surface so that the membrane itself sloped- – *” per foot minimum, *” per foot maximum- – to the weep holes in the bottom portion of the floor drain.

Prior to this, it had been customary to place the membrane flat, thus allowing seepage water to accumulate with no way to reach the weep holes and go down the drainpipe.

Shower floors are smaller than roof decks, but the same engineering principles apply. Slope the structure and Composeal Gold Waterproof Membrane to the weep holes in the floor drains; if there are no floor drains, slope to the open scuppers, with nothing in the bottom of the scuppers to prevent the free flow of seepage water.

FLAT DECK STRUCTURES

No matter how hard we try to spread the word about sloping them, structures continues to be built flat. The point of sloping the structure, which in turn slopes the membrane placed upon it, is to eliminate seepage water via the weep holes or open scuppers. The tile trade uses dry-pack floor mortar, and when this is placed on the flat waterproof membrane, the slope is only on the top surface of the dry pack. The dry pack is pumped out by the hot sun, leaving the salts of efflorescence on the tile. At least one company’s remedy for flat roof construction is to pre-float the roof deck with the dry pack mortar, which is then cover-cured. A waterproof membrane, designed to be used with a thin-set bonding system, is bonded to the mortar bed and fastened into the clamp-style floor drain. A compatible bonding mortar is then used to bond the tile to the membrane.

A SEEPAGE CHANNEL

In the design of roof decks, an effort has been made not only to slope the roof deck, but to create a channel which makes it easy for seepage water to flow toward the drain and into the weep holes. Until quite recently, the standard channel consisted of a layer of crushed rock over the waterproof membrane. A layer of cloth, such as burlap, was then placed over the crushed rock to prevent the mortar from filling up the voids in the crushed rock when the mortar bed was installed.

Now we have matting to provide that channel. The matting comes with a flannel – like cloth covering, which is installed cloth side up to prevent the mortar from filling in the extruded nylon and black spinnerette fibers. This type of matting has a long history of successful use in providing weep channels under concrete in drainage ditches and in similar situations.

An installation showing the use of the channel to promote water runoff is contained in the Handbook of Tile Installation. Even though this is the recommended way to install tile on roof decks, in actual practice, the channel is not always used. No matter what is done, however, positioning the waterproof membrane on a slope to the weep holes, or open scuppers, is the most important requirement for roof deck construction.

WATER ACCUMULATION

If the walls surrounding the roof deck are properly flashed at the juncture of deck and walls, and drip screeds are used, some water is going to drain across the tiled deck in addition to the rain which falls upon it naturally. However, it is best to not use the deck as a collection basin for water drainage; on the contrary, as much water should be kept off the roof decks as possible.

Directing water to the drains or scuppers takes some planning as to the positioning of those structures. Getting the water to move requires a slope of *” per foot. One – eighth of an inch per foot will drain the water, but will take much longer to do it; *” per foot, on a long run, may not be achievable because of the thickness build-up from the furthermost distance from the drain to the drain. To prevent problems, planning is needed as to the placement of the drains, as well as the height of the tracks for doors and sliding doors. Many, many times we have received calls describing situations in which only *” is available at the doorway to install a 2″ thick tile installation, and there is no way to drain the deck.

SUMMARY

“It’s only a roof deck!” As can be seen from the foregoing, construction of a roof deck takes planning. It is not difficult; it just has to be planned. It can also be seen that proper planning and execution require the cooperation of several trades working together.

Technical Data

COMPOSEAL 30 and 40 meet the engineering requirements of the American Society for Testing and Materials (ASTM) and the Ceramic Tile Institute (CTI). ASTM D4551 is the test standard established by ASTM

“for PVC flexible sheeting which is used with mastic, bedding or coating for construction of concealed water-containment membranes in applications where there is potential for costly secondary damage from water leakage and very long term reliable performance is essential. The tests are intended to ensure quality and performance.”

COMPOSEAL 30 and 40 meet and surpass these ASTM standards.

COMPOSEAL 30 and 40 also meet the CTI requirements for waterproof membranes.

TESTED MATERIAL

CERAMIC TILE INSTITUTE OF AMERICA

These tests were conducted by the United States Testing Co., Test Report No. LA 63554, Smith Emery Co., Test No. T-88-122A-B, and Truesdail Laboratories, Report # 24371-1.

Tile work shall comply with recommendations of “Handbook for Ceramic Tile Installation” published by the Tile Council of America, Inc., P.O. Box 2222, Princeton, N.J. 08543

* These drawings based on sketches in “Handbook for Ceramic Tile Installation.”

Engineering Properties ASTM D 4551 SpecGrade 30 ASTM D 4551 SpecGrade 40 Composeal Test Results .030 Composeal Test Results .030
Thickness, inches 0.30″ 0.40″ 0.31″ 0.42
Tensile Strength. lbs/in. width 60-lb min. 80-lb min. 89-lb (2870 psi) 113-lb (2700 psi)
Tensile Strength. at 100% elongation 30-lb min. 40-lb min. 43-lb 57-lb
Ultimate elongation before breaking 300% Min 300% Min 400% + 400% +
Tear Resistance. lbs/in width 185-lb min. 250-lb min. 260-lb 263-lb
Pinholes None None None None
Micro-Organism Resistance (fungus, mildew, mold) No Growth No Growth No Growth No Growth
Chemical Resistance:
Distilled H2O % wt. change* 1% max 1% max + 0.4% + 0.4%
Soapy H2O % wt. change* 2% max 2% max + 0.5% + 0.3%
Alkali, pass/fail (hydrostatic) Pass Pass Pass Pass
Shrinkage, dimension change at 158 F ASTM 1204 5% max 5% max 1.3% 2.9%
Volatility, % loss at 158 F after aging 1.5% max 1.5% max None None
Hydrostatic pressure (to test water penetration):
Original Condition Pass Pass Pass Pass
After Folding test (cold crack, 4hrs @ 0F) Pass Pass Pass Pass
After Puncture test Pass Pass Pass Pass
After Indentation test Pass Pass Pass Pass

No evidence of surface wetness or other signs of water penetration was detected on any of the tested specimens.

Additional Test :

Seam, (lap joint) strength ASTM D751 CTI Standard – 8 lbs./in. min. / Composeal 30 – 69 lbs./inch / Composeal 40 – 85 lbs./inch

Specific Gravity: 1.29 @ g/cm3

Cold Crack: passed @ 53 F

ASTM Standard D1004, d 412 d1790, e 96 and FHA Spec. 4900.1 are also met by Composeal

*Measure of water/ chemical surface absorption

Made in USA – 100% American Labor and Materials.

Composeal Gold Installation Instructions

Composeal Blue Vinyl Shower Pan Membrane How to Install

Free Natural Stone Training Teleconference!

4 Day Advanced Natural Stone Restoration! – FREE ENTRY

Date: Tuesday, March 12h
Time:
4:00 pm PST, 5:00 pm MST, 6:00 pm CST, 7:00 pm EST

Join us on Tuesday, March 12h and find out how you can easily add $200,000 to your bottom line this year restoring natural stone using the easiest, green method available,Cheetah Pads!!

We will be joined by several recent graduates of our advanced 4 day trainings that are eager to share first hand what they have learned!

Conference Dial-In #: 530-881-1300
Special Access Code:
226515#

Click Here To Register Now!

The class size is limited to a small number of attendees to ensure that you get maximium hands-on time with the equipment so that you have the confidence to go back to your company and immediately apply what you’ve learned. You will be able to create better than factory finish on floors, countertops and vertical surfaces.

Come and learn how to turn those “Before” to “After”

Counter top before and after

Floor Before and After

Are you achieving these kind of results? This restoration was performed on an over 100 year old installation. The only things used were Cheetah Pads and water!!
Are you making the kind of money you want?
Does your average job total make you happy??
Do you want to really see your profits skyrocket this year???
Now is the time to begin taking the steps that you need to have your best year ever!!
  
 We’d like to invite you to join us on this special live teleconference on Tuesday, March 12th to hear from other real life business owners, just like you! See how they have made tremendous progress and grown their bottom lines and exploded their potential to earn!!
This is not a boring, sit in a class room and watch a power point training class. Come and learn first hand from the manufacturer how simple natural stone restoration can be.

Please call us directly at tel: 800-280-0333 with any additional questions that you may have about our products and trainings and to reserve your spot today!!

Buy Restoration pads

Restoration of 100 year old Marble with Eco Friendly Pads

Restoration of 100 year old Marble

Before and After pictures of an almost 100 year old marble

This work was done by guys with no stone experience. We just walked them through the process.

If he can do it you can too

Deep scratches, gouges, burns, stains and etching everywhere. No two tiles were level with each other and to make it MUCH more complicated, there’s black granite inlayed at every intersection. It was beat up really bad.

AFTER Cheetah Pads steps 1-4 and a quick buff with 11,000 grit polishing pad. Absolutely crystal clear reflection.
The best the factory can do on this bad condition marble is 80-85 on the gloss meter. If we hit 90 we would’ve done a fantastic job, we hit 104.7. That kind of gloss and clarity isn’t even possible with any other system due to the huge differences in mineral composition in the marble and black granite. No problem for Cheetah Pads though.

Picture 1 –  before

Picture 2 – After

Picture – After

Picture 4 – After

Not bad for a 100 year old floor huh?

Restoration Training class is available come and learns how to turn those “Before” to “After”

FOR MORE INFO CALL
877 880 8453 or 323 731 8453

Buy Now

Flooring Supply Shop Blog | Flooring and Floor Heating Supply - Part 15